Carlo Gavazzi’s new RSGT Series Soft Starters are built for AC 3-phase induction motors up to 75Hp / 55kW. To maximize the ease of use without compromising performance, only three settings are required (FLC, ramp-up, ramp-down). The self-learning algorithm adjusts the soft starter’s parameters to work with different applications and varying load conditions. The integration of a Class 10 electronic overload provides advanced motor protection and results in further space savings in the electrical panel. Phase sequence protection, overload function, and dry run function can easily be enabled or disabled through the front located TEST/RESET push button.
FEATURES:
- Three Frame Sizes:
- 45mm width: Up to 25AAC / 20Hp / 15kW.
- 75mm width: Up to 55AAC / 50Hp / 37kW.
- 120mm width: Up to 90AAC / 75Hp / 55kW.
- Self-learning algorithm optimizes motor starts in all conditions.
- Robust design allows up to 12 starts per hour.
- Torque controlled ramp down: smoother deceleration of pumps.
- Real-time monitoring via Modbus RTU communications via RS485.
- Versions up to 400VAC are internally supplied, reducing wiring.
- Dry run detection (suitable for detecting pumps running dry).
RSGT Series Self-Learning 3-Phase Soft Starters
Carlo Gavazzi Technical Datasheets